Majestic Artisan Linear Vent Free Fireplace with Command Control - 42 Inch. Majestic Majestic Artisan Linear Vent Free Fireplace with Command Control - 42 Inch. Our Price: $1,926.90. Samsung galaxy grand prime manual download. It will occasionally need a touch up thanks to normal wear and tear. This trim kit - made for Majestic's 42-inch, vent-free Artisan piece.
Advertising
Majestic Echelon II 60' Gas Fireplace The new Majestic Echelon II Linear Gas Fireplace Available in multiple lengths, utilizes the newest technology for ignition and fire control. Requires a front to complete your new majestic fireplace. Model: Majestic ECHEL72IN. Buy the Majestic Echelon II 72 Inch Linear Direct Vent Gas Fireplace. Find info on price, framing dimensions, vent configurations, installation and accessories. Available in natural gas or propane. At North Country Fire we strive to provide the best customer care including industry leading technical support.
69D0023
41
Vermont Castings Wood Stove Parts, Majestic Wood Fireplace Parts, Majestic Gas Fireplace Parts, Dutchwest Wood Stove Parts, Century Wood Stove Parts, Insta-Flame Gas. Find the user manual you need for your home appliance products and more at ManualsOnline. Majestic Appliances Indoor Fireplace 33LDVR. Majestic Owner's Manual Fireplace 360DVS2, 360DVS3, 360DVSL, 360DVSR. See Prices; Majestic Appliances Indoor Fireplace 360DVS3. Majestic Owner's Manual Fireplace 360DVS2, 360DVS3, 360DVSL.
STANDING PILOT IGNITION
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
ACTION
1. Spark
ignitor Native instruments setup maschine 2.0.
will not light
pilot after repeated trig- gering of piezo.
A. Wire disconnected.
B. Defective ignitor.
C. No gas or low gas pressure.
D. No Propane/LPG in tank
A. Open door and check to make sure wire is connected to ignitor.
B. Check for spark at electrode and pilot. If no spark and electrode
wire is properly connected, replace pilot assembly.
C. Check remote/manual shut off valve from fireplace. Low pressure
can be caused by bent lines, restricted lines, low pressure line
pressure. Consult with plumber or gas supplier.
D. Check Propane/LPG tank. Refill tank.
2. Pilot will not
stay lit after
carefully fol- lowing light- ing instruc- tions.
A. Defective thermocouple
B. Defective valve
A. Check that thermocouple flame impinges on thermocouple. Clean
and/or adjust pilot for maximum flame impingement. Ensure that
the thermocouple connection at the gas valve is fully inserted and tight.
Disconnect the thermocouple from the valve, place one millivolt
lead wire on the tip of the thermocouple and the other meter lead
wire on the thermocouple copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 mV, replace pilot assembly.
B. If thermocouple is producing more than 15 mV, replace faulty
valve.
3. Pilot
burning,
valve knob
turned to “ON”, switch is turned to “ON” or “RS”, but burner will not ignite.
A. Defective switch, wall switch,
remote control or wire
B. Pilot flame too small
C. Defective or malfunctioning ther- Dead space 3 game download for android.
mopile
D. Defective valve
A. Check switch and wire for proper connection. Place jumper wires
across terminals of switch. If burner comes on, replace defective
switch.If the switch is OK, repeat the same procedure on remote control If burner comes on, replace remote control.
Place jumper wire across wire at gas valves (terminals marked TH
and TP/TH). If burner comes on, wires are faulty or connections
are bad. Replace wire.
B. If pilot flame is not close enough to the thermopile, adjust pilot
flame.
C. Check thermopile wire connections to make sure all are tight and
that the thermopile is fully inserted into pilot assembly. Check
thermopile with a millivolt meter. Connect leads to TP and TP/TH terminals on the control valve. If meter reading is below 325 mV, replace pilot assembly.
D. Turn valve knob to “On” and switch to “ON.” Take a reading at
the thermopile leads (TP & TP/TH) on the valve. If the meter
reads greater than 175 mV and the burner does not light, replace defective valve.
4. Frequent
pilot
outage prob-
lem.
A. Pilot flame may be too high or too
low, causing pilot safety to drop
out
A. Clean and adjust the pilot flame for maximum flame impingement
on thermocouple.
5. The pilot and
main burner
extinguish while in oper- ation
A. Inner vent pipe leaking exhaust
gases back into system
B. Horizontal vent improperly pitched
C. Improper vent cap installation
A. Check for flue product leak. Replace defective pipe section.
B. Check horizontal-venting piping is running upward 1/4' per foot.
Uvc36rn Majestic Fireplace Manual
Do not run the pipe level or downward.
C. Check for proper installation and freedom from debris or blockage
Advertising
Majestic Ventless Fireplace Systems
Popular Brands
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |